Skip to content
Review

Artificial Intelligence-Enabled Acquisition and Interpretation for Screening Aortic Stenosis.

Aug 2026 · JAMA cardiology · 1 citation · 31 references
Medicine

TL;DR

A deep learning algorithm accurately detected moderate or greater AS across validation cohorts in this study and support a scalable strategy that may expand access to AS detection in settings with limited echocardiography resources.

Abstract

Importance Timely identification of aortic stenosis (AS) is essential for appropriate clinical management, yet screening remains limited by dependence on comprehensive echocardiography and trained imaging personnel. Objective To develop and validate a deep learning algorithm for detection of moderate or greater AS and prospectively evaluate its performance using artificial intelligence (AI)-guided focused cardiac ultrasound (FoCUS) acquired by novice operators. Design, Setting, and Participants This diagnostic study included retrospective algorithm development and validation and prospective evaluation of AI-guided FoCUS across Mayo Clinic sites in the Midwest, Arizona, and Florida. The model was developed using 6753 patients and evaluated in internal validation (n = 852), internal test (n = 844), and validation (n = 1912) cohorts. Performance was assessed on FoCUS acquired by experienced sonographers (n = 602) and prospectively by novice operators (n = 1302). The retrospective model development and validation cohorts comprised studies performed from January 2005 through September 2022. Prospective study was conducted in 2 enrollment periods from June to August 2024 and from June to September 2025. Participants from both periods were combined to comprise the final prospective cohort. Exposure AI-guided FoCUS acquisition and automated deep learning-based assessment for detection of moderate or greater AS. Main Outcomes and Measures Detection of moderate or greater AS. Performance was assessed using area under the receiver operating characteristic curve (AUROC), sensitivity, specificity, and positive predictive value. Results The model demonstrated excellent discrimination in the internal test cohort (AUROC, 0.99; 95% CI, 0.98-1.00) and geographically distinct validation cohorts in Arizona (AUROC, 0.99; 95% CI, 0.97-1.00) and Florida (AUROC, 0.99; 95% CI, 0.96-1.00). Among FoCUS examinations acquired by experienced sonographers, sensitivity was 95% (95% CI, 82-99) and specificity was 97% (95% CI, 95-98). In the prospective novice-operator cohort, 1258 of 1302 examinations (96.6%) were suitable for automated analysis. Sensitivity was 93% (95% CI, 82-99) and specificity was 96% (95% CI, 95-97). Expert review of AI-positive and uninterpretable examinations increased the positive predictive value from 49.4% to 91.1%, with sensitivity of 85.4%. Conclusions and Relevance A deep learning algorithm accurately detected moderate or greater AS across validation cohorts in this study. In prospective evaluation, novice operators were able to acquire AI-guided FoCUS examinations that enabled accurate detection of moderate or greater AS. These findings support a scalable strategy that may expand access to AS detection in settings with limited echocardiography resources.

View source

Similar papers

Open access Sep 2026

Automated Aortic Valve Calcification Scoring: Multicenter External Validation of a Deep Learning Algorithm.

BACKGROUND Aortic valve calcification (AVC) quantification is a guideline-recommended imaging biomarker for aortic stenosis (AS) severity and progression yet remains underreported on routine chest computed tomography (CT). With nearly 20 million nongated chest CTs performed annually in the United States, automated AVC...

Jimmy Zheng, Eren Alkan, Aniruddha K. Deshpande et al. · 0 citations
Review Open access Sep 2026

Artificial Intelligence in Echocardiography and Point-of-Care Ultrasound: Applications, Clinical Integration, and Future Directions

Artificial intelligence (AI) is increasingly used in echocardiography and point-of-care ultrasound (POCUS) to support image acquisition, view recognition, image-quality assessment, segmentation, automated quantification, disease classification, reporting, and bedside decision support. This narrative review summarizes c...

F. Savorgnan, Pranathi Pilla, Sarah Visokay et al. · 0 citations
Review Aug 2026

Artificial Intelligence in Cardiovascular Imaging and Risk Stratification: From Algorithmic Discovery to Meaningful Clinical Implication.

It is emphasized that successful integration of AI into cardiovascular care requires rigorous prospective validation, transparent algorithmic governance, equitable data representation, and human-AI collaborative frameworks, provided its meaningful clinical implication is demonstrated through improved patient outcomes.

Xu Xia, Wasim Ullah Khan, Q. Khan et al. · 0 citations
Open access Sep 2026

Comparison of Artificial Intelligence-Driven Echocardiographic Assessment of Diastolic Function With the ASE Guidelines

Background Contemporary guideline-based assessment of left ventricular diastolic function and filling pressure requires multiple echocardiographic parameters that may not be routinely acquired in real-world clinical practice. Objectives The aim of the study was to compare the prognostic and diagnostic performance of a...

M. Tokodi, N. Kagiyama, Ambarish Pandey et al. · 0 citations

Current Medical Imaging

Ke-Xin Jiang, Wen-Yan Liu, Yang Xu et al. · 3 citations

Current Medical Imaging

Mei-Lan Zhang, Jing Li, Yan Wang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.