Effect of non-uniform turn-to-turn resistance on quench behavior of nested NI/MI REBCO magnets under open-circuit fault
The vulnerability of REBCO insert magnets to extreme mechanical responses during open-circuit faults has caused severe failures in some high-field systems. This work studies the fault behaviors of a nested no-insulation/metal-insulation (NI/MI) REBCO insert in a 30 T magnet using the rotated anisotropic resistivity met...