Study on Low-Velocity Impact Damage of Glass Fiber Reinforced Composite Pipeline
Through low-velocity impact testing, the effects of punch shape (conical, hemispherical, and cylindrical) and impact energy (5, 10, and 15 J) on damage characteristics in glass fiber composite pipes were investigated. Ultrasonic A-scan inspection was employed to detect internal delamination damage at the impact points...