Skip to content

Author

Shahrokh Abadi

1 paper indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Open access Jul 2026

A Monolithic, Thiol-Functionalized Au-Based Bio-CMOS Aptasensor for Rapid, Label-Free Detection of Escherichia coli O157:H7 in Patient-Derived and Hospital-Acquired Specimens

Rapid, point-of-care detection of Escherichia coli O157:H7 remains an unmet clinical need, as culture and molecular methods are slow and poorly suited to decentralized or emergency settings. A label-free, monolithic aptasensor biochip was fabricated in a standard 65 nm CMOS process, featuring three aptamer-functionalized gold sensing pads with matched reference pads for differential readout. A 37-mer DNA aptamer targeting the E. coli O157:H7 lipopolysaccharide was immobilized via thiol–gold self-assembled monolayer chemistry. Binding events were transduced into surface-potential shifts, amplified by an on-chip analog front-end (~100 V/V gain, 101.5 µW), and evaluated using calibration standards, patient specimens, and hospital environmental samples, with fluorescence microscopy for validation. The sensor achieved 47.42 mV/decade sensitivity across 1–10,000 CFU/mL, an IUPAC detection limit near 3.74 CFU/mL, and an empirical LOD of about 11 CFU/mL, with outputs tracking bacterial load and ~5.7% matrix-related deviation. Hospital samples were detectable to 28 CFU/mL. Because the patient-derived and hospital-acquired cohorts (n = 10 and n = 6, respectively) were assembled for pilot analytical and matrix-tolerance characterization rather than for diagnostic-accuracy determination, these results establish detectability and matrix robustness in real clinical and environmental specimens rather than clinical diagnostic sensitivity or specificity, which will require a larger, prospectively enrolled cohort in future work. Sensor kinetics followed Langmuir-type adsorption, saturating within 16–25 min for target pathogens versus slower responses for non-target strains. Selectivity tests against six bacterial species showed discrimination, with cross-reactivity decreasing from related E. coli pathotypes to Enterobacteriaceae to Gram-positive species. Inter-pad variability stayed below 1.5 mV, supporting this compact, low-power platform for scalable, enrichment-free point-of-care pathogen detection.

Z. Nejad, Shahrokh Abadi, M. H. Shahrokh Abadi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.