Skip to content

2 papers indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Open access Jul 2026

Ventricular Tachycardia Ablation in Structural Heart Disease With LVEF > 35%: Clinical Outcomes and Recurrence Patterns.

BACKGROUND In patients with structural heart disease (SHD) and moderately impaired left ventricular ejection fraction (LVEF > 35%), data on outcomes after ventricular tachycardia (VT) ablation remain limited. This analysis focuses on VT recurrence after ablation in patients presenting with sustained VT and LVEF > 35% within a secondary-prevention population. OBJECTIVE To evaluate procedural outcomes and long-term VT recurrence after catheter ablation in SHD patients with LVEF > 35%. METHODS We analyzed 219 consecutive patients with SHD and LVEF > 35% undergoing VT ablation, including 89 with ischemic cardiomyopathy (ICM) and 130 with non-ischemic cardiomyopathy (NICM). Procedural characteristics, complications, and VT recurrence during follow-up were compared between groups. RESULTS ICM patients were older, more frequently hypertensive, and had slightly lower LVEF than NICM patients. Ablation was predominantly endocardial in ICM, whereas combined endocardial-epicardial ablation was required in 28% of NICM patients (p < 0.001). Acute VT non-inducibility was achieved more frequently in ICM than in NICM (93% vs 67%; p < 0.001). Procedural complications were infrequent and comparable between groups (6% overall; p = 0.342). During follow-up, VT recurred in 35% of patients, more frequently in NICM than ICM (42% vs 25%; p = 0.004). Cardiomyopathy type emerged as the only independent predictor of VT recurrence (HR 2.312, CI 1.3-4.0, p = 0.004), while acute non-inducibility was associated with a lower recurrence risk. CONCLUSION VT ablation in SHD patients with LVEF > 35% was associated with acceptable safety and moderate arrhythmia control. Outcomes were more favorable in ICM than in NICM, reflecting the heterogeneity of arrhythmic risk in this secondary prevention population.

Said-Elias Waezsasa, M. Khalaph, M. Braun et al. · 0 citations
Open access Jul 2026

Impact of ICD Presence in Patients With Left Ventricular Assist Devices for End-Stage Heart Failure.

BACKGROUND The prognostic relevance of implantable cardioverter defibrillator (ICD) in patients with end-stage heart failure (HF) with left ventricular assist device (LVAD) remains controversial. OBJECTIVES To evaluate the prognostic impact of ongoing use of ICD and associated complications in HF-patients with LVAD-implantation. METHODS We retrospectively analyzed all consecutive patients (n = 351) who underwent LVAD-implantation and follow up between 2009 and 2021. Patients were categorized according to the presence (n = 254) or absence (n = 97) of ICD. To reduce baseline imbalances between groups, propensity score matching (PSM) was performed, yielding two matched cohorts of 79 patients each. The primary endpoint was a composite of all-cause mortality and heart transplantation. Secondary endpoints included all-cause mortality, heart transplantation, and ICD-related complications. RESULTS Median age was 58 [49-65] years, and 85% were male. Median follow-up duration was 3.6 [2.6-5.7] years. The primary endpoint revealed significantly less events in the ICD cohort (44.3% vs. 59.5% (HR 0.6 95%CI [0.40; 0.97], p = 0.035)). The difference was driven by a higher rate of all-cause mortality (22.08% vs. 41.8%, p = 0.008), while the heart transplantation rate was similar (17.7% vs. 21.5%, p = 0.98). ICD-related complications occurred in 20.4% of all ICD-patients, including 27 lead revisions, 8 complete system removals due to infection, 13 inadequate shocks and 4 hematoma evacuations. CONCLUSION ICD therapy was associated with lower mortality in this single-center LVAD-cohort. However, this finding contrasts with recent meta-analytic. Given the substantial burden of ICD-related complications, ICD-management after LVAD-implantation should be individualized according to arrhythmic risk, pacing requirements, procedural risk, and patient preferences.

N. Baridwan, Mustafa Gerçek, M. Gerçek et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.