Author

G. Pedrazzini

1 paper indexed here

Fetches their full publication history.

Not the right person? Other researchers publish under this name.

#small language model Review Open access Aug 2026

Quality, consistency, and clinical safety of AI-generated versus clinician-written clinical notes: a multi-country paired simulation study

Background Ambient AI documentation tools, known as scribes, are entering routine clinical practice at scale, but the evidence comparing the notes they produce against clinician-written notes is dominated by single-site, single-language studies that rely on human review to find errors, a method known to miss most documentation errors. Methods We conducted a paired simulation across five countries and languages (Cambridge/English, Barcelona/Spanish, Milan/Italian, Paris/French, Cologne/German; 385 paired consultations, 770 notes). From each actor-performed consultation, an AI scribe (Heidi) and a junior-to-middle-grade clinician independently produced a note. Notes were scored on the PDQI-9 by evaluators blinded to authorship. Documentation errors were identified by two methods of deliberately different sensitivity - clinician adjudication, and a calibrated automated reviewer externally validated against a blinded ten-clinician panel - then graded for clinical risk by a three-model panel. The co-primary outcomes were PDQI-9 total and Critical+High error burden, the latter reported under both detection arms. The analysis plan was registered before any pooling across sites. Results AI notes scored higher than clinician notes on the PDQI-9 (40.6 vs 35.6; difference +5.08, 95% CI 4.6-5.6; Cohen dz=0.55), consistently across all five sites (dz 0.41-0.75), and were less dispersed (5.7% of AI vs 27.8% of clinician notes fell below the study pre-specified low-score threshold (<32)). On the principal safety outcome - the paired probability that a note carried [≥]Critical+High error - clinician notes were affected more often under both detection arms: 61.0% versus 24.4% by the calibrated reviewer (relative risk 2.50, 95% CI 2.09-3.00) and 21.8% versus 6.2% by clinician adjudication (relative risk 3.50, 95% CI 2.32-5.27). The difference was largest for omissions. Unaided clinician review identified roughly 12% of the errors the calibrated reviewer retained, and a smaller fraction in AI notes than in clinician notes. Conclusions In this simulation, AI-generated notes scored higher on documentation quality, varied less, and carried fewer clinically significant errors than notes written on the same consultations by junior-to-middle-grade clinicians. The magnitude of the safety difference depends on the sensitivity of error detection, so we report both detection regimes and bound rather than point-estimate the absolute error rate. Extension to live practice, consultant-authored documentation, and notes as filed after clinician editing remains to be established.

H. Bergman, V. Liu, B. Austin et al. · 0 citations