Skip to content

Author

G. de Donato

1 paper indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Open access Aug 2026

The ECO-PLUG Technique: Ultrasound-Guided Optimization of Haemostasis After Percutaneous Femoral Access - a Pictorial Technical Note.

PURPOSE To describe the ECO-PLUG technique, a standardised ultrasound-guided workflow for percutaneous femoral access and plug-based closure, and to report its feasibility and clinical performance in patients undergoing peripheral artery revascularization procedures. TECHNIQUE The ECO-PLUG protocol incorporates continuous ultrasound guidance throughout all procedural phases: femoral access, closure device deployment, and post-procedural haemostasis verification. Five predefined checkpoints (C1-C5) structure the workflow from pre-access mapping to early and delayed ultrasound follow-up. Key elements include in-plane puncture, ultrasound-guided plug deployment with a modified retract manoeuvre, and systematic colour-Doppler assessment at 0 and 3 to 5 minutes after closure. RESULTS A total of 200 elective endovascular procedures using 6F/8F femoral access were analysed. Anatomical complexity was common, including moderate-to-severe anterior wall calcification (55%), arterial depth >35 mm (24%), and bifurcation variants (22%). Immediate haemostasis was achieved in 98% of cases, while 2% required prolonged compression or manual conversion. Access-related complications occurred in 4% of patients, including pseudoaneurysms (1.5%) and haematomas. No arterial occlusions or surgical conversions were observed. CONCLUSIONS The ECO-PLUG protocol demonstrates acceptable haemostasis efficacy and a favourable access-site safety profile across anatomically complex settings, supporting its potential as a structured image-guided closure strategy. Prospective comparative studies are needed to validate these preliminary findings.Clinical ImpactThe ECO-PLUG protocol introduces the first formally structured, checkpoint-based ultrasound workflow integrating continuous imaging guidance across all phases of percutaneous femoral closure, from pre-access mapping through plug deployment and hemostasis verification. Unlike conventional approaches, where ultrasound use is typically limited to arterial puncture alone, ECO-PLUG extends real-time sonographic control to anchor positioning and collagen release, reducing operator dependency in anatomically complex cases. With 98% immediate hemostasis and no arterial occlusions or surgical conversions across 200 consecutive procedures, including patients with heavy calcification, deep vessels, and bifurcation variants, this protocol offers clinicians a reproducible, teachable standard applicable across varying experience levels.

E. Pasqui, Leonardo Pasquetti, M. Anzaldi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.